Maintenance with the QuickService concept
The easy to maintain progressive cavity pumps
The CC series boasts the innovative QuickService concept, which offers multiple possibilities for replacement of the rotor and stator and for sealing change.
Fast changing of parts
If the pump needs to be operational again as quickly as possible, the stator and rotor are replaced as a single unit. It is also possible to replace the entire rotating unit without dismounting parts of the pipe on either the suction or discharge sides. To do this, simply remove the screws on the angled flange connection and on the pump housing. The unit can then be swiveled upwards or to the side, after which it can be removed and replaced with a new unit. The replaced unit is then reconditioned while the pump is back in service – either by the operator itself or by our service department or one of our pump service partners.
Changing individual components
Alternatively, as with a conventional progressive cavity pump, once the rotor-stator unit has been swiveled out, you can also remove and replace just the stator. If necessary, you can also replace the rotor separately.
Practical sealing change in the CC series
The CC series progressive cavity pumps also offer two options for changing the Quality Cartridge mechanical seal. It can be replaced from the drive end, quickly and completely independently of work on the pumping elements, once the parallel shaft geared motor is removed. Alternatively, the Quality Cartridge can be replaced through the pump housing after the cardan shaft has been removed.